How to properly set the MicroValve

3 Problems when you flood the pusher line with abrasive

  1. You waste abrasive
  2. You impede the blast by compromising optimal pressure
  3. You compromise the substrate’s profile

How to properly dial in and set the Microvalve

  1. Completely close the MicroValve – and then open it 3.5-4 dial rotations
  2. Hold the nozzle up to the light, allowing the abrasive to exit the blast stream into the air.  You should be able to see a small bluish jet stream protruding at the very tip of the blast nozzle.
    • If there is too much abrasive, the bluish jet stream will not be visible and the noise of the nozzle will soften and dampen.
    • If there is too little abrasive, the bluish jet stream will also not be visible, but the sound of the nozzle will produce a higher shrill (scream) than what is heard when proper abrasive exits the venturi.

 

We want to know what questions, challenges, and problems you’re facing – either with blasting or painting – that we may be able to solve.

If you find our insights helpful, please subscribe and share our channel.

Read More Posts

Blast Hose Safety Checklist

BLASTHOSE SAFETY CHECKLIST Quick daily inspection steps for blast hose, couplings, and nozzle holders. Daily Use Checklist ✅ Daily Inspection Perform a visual check of the entire hose before blasting. Look for cracks, splits, bubbles, or holes in the outer casing. Inspect hose couplings for tight fit, damage, or excessive wear. ✅ Squeeze Test Squeeze […]

Add to quote:

Registration is required to create a Quote.

Click Here to Login or Register.

Add to existing quote:

Add to Quote

Add to a new quote:

Send the request

BlastOne says
Thank you for submitting your quote. A sales representative will follow up with you asap.
Share Quote via Email

Share